earticle

논문검색

Original Article

깃각 자동측정 프로그램의 신뢰도와 타당도 평가

원문정보

An Evaluation of the Reliability and Validity of the Automatic Pennation Angle Measuring Program

김종순

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Purpose: Ultrasound imaging is commonly used to measure the pennation angle of human skeletal muscles in vivo. However, manual assessment of the pennation angle using ultrasound images is subjective and time-consuming and requires a high level of examiner skill. The architectural analysis of human skeletal muscles is thus challenging. Automated approaches using image processing techniques are therefore required to estimate the pennation angle in ultrasound images. The purpose of this study was thus to assess the intra-tester and inter-tester reliability and validity of the pennation angle using an automatic measurement program. Methods: Twenty-two healthy young adults (mean age = 22.55 years) with no medical history of neurological or musculoskeletal disorders voluntarily participated in this study. Ultrasound imaging was used to measure the pennation angle of the gastrocnemius muscle at rest. One examiner acquired images from all the participants. The intra-tester and inter-tester reliability were evaluated using the intraclass correlation coefficient (ICC) to estimate reliability. Validity was measured using Pearson’s correlation coefficient. Results: The intra-rater reliability was excellent for the automatic pennation angle measuring program and the manual pennation angle assessment method (ICC>0.95). The inter-rater reliability was also excellent for both methods (ICC>0.93). All the correlation coefficients for the automatic pennation angle measuring program and the manual pennation angle assessment method were 0.79, which indicated a significantly positive correlation (p<0.05). Conclusion: Pennation angle measurement using the automatic pennation angle measuring program showed acceptable reliability and validity. This study therefore demonstrated that the automatic measuring program was able to automatically measure the pennation angle of skeletal muscles using ultrasound images, and thus made it easy to investigate skeletal muscle architecture.

목차

Abstract
Ⅰ. 서론
Ⅱ. 연구 방법
1. 연구 대상
2. 측정방법 및 도구
3. 깃각 측정 절차
4. 자료 분석
Ⅲ. 연구 결과
1. 측정방법에 따른 측정자내 신뢰도
2. 측정방법에 따른 측정자간 신뢰도
3. 깃각 자동측정 프로그램의 타당도
Ⅳ. 고찰
Ⅴ. 결론
References

저자정보

  • 김종순 Jong-Soon Kim. 부산가톨릭대학교 보건과학대학 물리치료학과

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

      0개의 논문이 장바구니에 담겼습니다.