earticle

논문검색

<학술연구>

회전 분무장치에서 작동조건의 변화가 미립화 성능에 미치는 영향

원문정보

Effect of Variation of Operating Conditions on Atomization Performance in Rotary Atomizer

김형곤

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

In order to apply rotary atomizer to agricultural spraying system, the motor direct coupled rotary atomizer was proposed. The effect of operating conditions such as atomizing air flow rate, working fluid flow rate, and rotation speed of spinning cup on the atomization performance was investigated for the proposed direct coupled rotary atomizer. The motor speed was controlled in the range of 6,000 to 12,000 rpm using an alternating current transformer, and the atomizing air was supplied by the compressor. In this study, LDPA was used to analyze the spray characteristics of the rotary atomizer. The representative particle diameters of D10, SMD, MMD, D90, and DMax tended to decrease as the atomizing air flow rate and the motor speed increased, but increased as the working fluid flow rate increased. Also, SMD was found to be influenced by order of atomizing air flow rate> motor speed> working fluid flow rate, and DMax was influenced by order of operating fluid supply> motor speed> atomizing air flow rate.

목차

ABSTRACT
1. 서론
2. Experimental apparatus and Methods
3. 실험결과 및 토론
3.1 액적 크기 분포
3.2 액적 직경
4. 결론
References

저자정보

  • 김형곤 Hyung Gon Kim. Member, CAMSTech Co.,LTD.

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원