Plan-Class Specific Reference Quality Assurance for Volumetric Modulated Arc Therapy

원문정보

초록

영어

Background: There have been much efforts to develop the proper and realistic machine Quality Assurance (QA) reflecting on real Volumetric Modulated Arc Therapy (VMAT) plan. In this work we propose and test a special VMAT plan of plan-class specific (pcsr) QA, as a machine QA so that it might be a good solution to supplement weak point of present machine QA to make it more realistic for VMAT treatment. Materials and Methods: We divided human body into 5 treatment sites: brain, head and neck, chest, abdomen, and pelvis. One plan for each treatment site was selected from real VMAT cases and contours were mapped into the computational human phantom where the same plan as real VMAT plan was created and called plan-class specific reference (pcsr) QA plan. We delivered this pcsr QA plan on a daily basis over the full research period and tracked how much MLC movement and dosimetric error occurred in regular delivery. Several real patients under treatments were also tracked to test the usefulness of pcsr QA through comparisons between them. We used dynalog file viewer (DFV) and Dynalog file to analyze position and speed of individual MLC leaf. The gamma pass rate from portal dosimetry for different gamma criteria was analyzed to evaluate analyze dosimetric accuracy. Results and Discussion: The maxRMS of MLC position error for all plans were all within the tolerance limit of < 0.35 cm and the positional variation of maxPEs for both pcsr and real plans were observed very stable over the research session. Daily variations of maxRMS of MLC speed error and gamma pass rate for real VMAT plans were observed very comparable to those in their pcsr plans in good acceptable fluctuation. Conclusion: We believe that the newly proposed pcsr QA would be useful and helpful to predict the mid-term quality of real VMAT treatment delivery.

목차

ABSTRACT
Introduction
Materials and Methods
1. Plan classification
2. Creating pcsr QA plan
Results and Discussion
1. MLC movement analysis
2. Dosimetric analysis
CONCLUSION
ACKNOWLEDGEMENT
REFERENCES

저자정보

  • Mohammad Mahfujur Rahman Department of Nuclear Engineering, Hanyang University, Seoul, Korea
  • Chan Hyeong Kim Department of Nuclear Engineering, Hanyang University, Seoul, Korea
  • Seonghoon Kim Department of Radiation Oncology, Hanyang University Medical Center, Hanyang University, Seoul, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      0개의 논문이 장바구니에 담겼습니다.