원문정보
A Study on improvement of plating equipment for fire prevention
초록
영어
In this paper we developed the Teflon heater which contains a built in temperature sensor and a relay for improved plating equipment system. Teflon heater is improved by using Pt 100Ω sensor which can detect until 600°C. When the bath temperature sensor detects over 60°C or the Teflon heater sensor detects over 240°C they temporarily shut down the heater to control temperature. Also relay completely shuts down main power when detects instant temperature is detected over 5% of 240°C by the heater sensor to prevent teflon melting down and fire spreads. Developed plating equipment system can monitor a real time temperature in the teflon tube and bath water. Therefore we think the proposed plating equipment can eliminate the possibility of fire in plating processes fundamentally.
목차
1. 서론
1.1 연구 배경
1.2 선행 연구
1.3 선행 연구의 한계점
2. 본론
2.1 개선된 도금 장비 작동 방법
2.2 화재 발생 실험
3. 결론
4. 참고문헌