Cryogenic cooling system for a 154 kV/ 2 kA superconducting fault current limiter

초록

영어

A cryogenic cooling system is designed for a 154 kV/ 2 kA three-phase hybrid type superconducting fault current limiter (SFCL). The superconducting modules of the SFCL have the operating condition of 71 K at 500 kPa. The total heat load of the SFCL including the cooling system is estimated at 9.6 kW. The cooling system of the closed loop is configured to meet the operating condition, depending on cooling methods of forced flow cooling and re-liquefaction cooling. The cooling system is composed of three cryostats with superconducting modules, cryocoolers, liquid nitrogen circulation pumps, a subcooler and a pressure builder. The basic cooling concept is to circulate liquid nitrogen between three SFCL cryostats and the cryocooler, while maintaining the operating pressure. The design criterion for the cooling system is based on the operation results of the cooling system for a 154 kV/ 2 kA single-phase hybrid SFCL. The specifications of system components including the piping system are determined according to the design criterion.

목차

Abstract
1. INTRODUCTION
2. COOLING SYSTEM CONFIGURATION
3. SPECIFICATION OF SYSTEM COMPONENTS
3.1 Liquid nitrogen pump
3.2 Piping system
3.3 Heat exchanger for a subcooler
3.4 Subcooler
3.5 Pressure builder
4. SUMMARY
ACKNOWLEDGMENT
REFERENCES

저자정보

  • Sehwan In Korea Institute of Machinery and Materials, Daejeon, Korea
  • Yong-Ju Hong Korea Institute of Machinery and Materials, Daejeon, Korea
  • Hankil Yeom Korea Institute of Machinery and Materials, Daejeon, Korea
  • Junseok Ko Korea Institute of Machinery and Materials, Daejeon, Korea
  • Hyobong Kim Korea Institute of Machinery and Materials, Daejeon, Korea
  • Seong-Je Park Korea Institute of Machinery and Materials, Daejeon, Korea
  • Young-Hee Han Korea Electric Power Research Institute, Daejeon, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.