원문정보
Evaluation of fitness according to application of glass fiber reinforcement for lower jaw complete denture
초록
영어
Purpose: The purpose of this study is to evaluate the fitness of lower jaw compete denture with glass fiber. Methods: Lower jaw edentulous model was selected as the master model. Ten study models were produced using Type Ⅳ stone(n=10). Lower jaw trial dentures were produced by the wax denture base and artificial teeth. Conventional complete denture (CD) group was fabricated by excluding glass fiber reinforcement (n=5). Glass fiber complete denture (GD) group was fabricated with glass fiber reinforcement (n=5). The lower jaw trial complete denture was invested using a plaster. PMMA resin was injected and curing was performed. The CD and GD groups measured the fit using silicone replica technology. The measured data was verified by t-test. Results: The anterior area of the CD group showed the smallest value. There was a statistically significant difference in the anterior area of the CD group and the GD group (p<0.05), but there was no statistically significant difference in the posterior area (p>0.05). Conclusion : Complete denture with glass fiber showed low fitness and further study is needed to apply it clinically.
목차
I. 서론
II. 연구 방법
1. 주모형 제작
2. 연구모형 제작
3. 납의치 시적의치 제작
4. 납의치 시적의치의 매몰 및 왁스 제거
5. 일반 레진의치(Conventional complete denture, CD group) 제작
6. 유리섬유 보강재를 적용한 레진의치(Glass fiber complete denture, GD group) 제작
7. 적합도 평가
8. 통계분석
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
REFERENCES