Water Supply Scenarios in Response to Disaster Situations

원문정보

재난상황에 따른 용수공급대응 시나리오

Seung Seop Ahn, Kyo Sik Kim

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

The purpose of this study is to evaluate the water supply scenario when Daegu metropolitan area is out of water supply due to disaster. Deagu metropolitan area receives 60.5% of the total water supply from Nakdong river. In the scenario 1 assuming that the Maegok water purification plant cannot be operated, 250 lpcd of water supply can be provided with 80.4% reliability. In the scenario 2 assuming the Maegok and Munsan water purification plants are out of operation due to a water pollution accident in Nakdong river, it is possible to supply 205 lpcd of water with 60.4% reliability. As the results of the scenario-based study indicate, Deagu metropolitan area needs to develop the emergency response strategy for reliable water supply in case water supply from Nakdong river is in danger.

한국어

이 연구는 대구광역시의 상수도시설이 재난상황 발생에 따라 물을 생산하여 공급이 불가능하다는 가상의 시나리오를 설정하고 대구시에서 운영하는 각 5개의 정수장에서 용수를 공급할 수 있는 대응 에 대해서 검토하고자 하는 목적이 있다. 대구시는 전체 공급량의 60.5%를 낙동강을 수원으로 취수 하여 매곡과 문산정수장에서 공급하고 있다. 본 연구에 적용된 가상의 재난상황 시나리오는 각각의 정수장이 재난발생에 따라 운영이 불가능한 경우인 Scenario 1(a)~(e)와 매곡과 문산정수장이 운영불 가능한 경우인 Scenario 2를 가정하여 용수공급 대응방안에 대해 검토하였다. 그 결과 Scenario 1(a)~(e)에서는 매곡정수장이 운영이 불가능한 경우 대구광역시 전체의 용수공급 신뢰도 80.4%로 250 lpcd를 공급할 수 있으며, Scenario 2의 경우에는 60.4%의 신뢰도로 205 lpcd를 공급할 수 있는 것으로 검토되었다. 정수장의 운영불능이라는 가상의 재난상황에 대한 시나리오를 설정하여 대구광 역시의 용수공급방안을 검토한 결과 정수장 운영 불능상태에 따른 재난 상황에서 용수공급신뢰도를 높일 수 있는 대응전략이 필요한 것으로 판단된다.

목차

Abstract
Ⅰ. 서론
Ⅱ. 연구대상 유역 및 시나리오의 설정
1. 연구대상 유역
2. 재난 시나리오의 설정
Ⅲ. 시나리오에 따른 물공급분석
1. 정수장별 용수공급 현황
2. 재난 시나리오에 따른 물공급 분석
Ⅳ. 결론
감사의 글
References
국문초록

저자정보

  • Seung Seop Ahn School of Construction Engineering Kyungil University
  • Kyo Sik Kim Civil Engineering, Gyeongbuk Provincial College

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.