earticle

논문검색

Technical Paper

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

초록

영어

Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, 200 μA) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of Al2O3:C and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of Al2O3:C showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

목차

ABSTRACT
Introduction
Materials and Methods
1. Optical Stimulation Control and Optical Measurement Part
2. Thermal Stimulation and Sample Substrate
3. X-ray Irradiation Device
4. Construction of the Device
Results and Discussion
1. Output Characteristics of X-ray
2. RL-OSL Measurement Characteristics
3. RL-TL Measurement Characteristics
Conclusion
Acknowledgements
References

저자정보

  • Chang-Young Park Department of Physics and Research Institute of Natural Science, Gyeongsnag National University, Jinju, Korea
  • Young-Kook Park Department of Physics and Research Institute of Natural Science, Gyeongsnag National University, Jinju, Korea
  • Ki-Soo Chung Department of Physics and Research Institute of Natural Science, Gyeongsnag National University, Jinju, Korea
  • Jong-Duk Lee College of Interdisciplinary and Creative Studies, Konyang University, Nonsan, Korea
  • Jungil Lee Korea Atomic Energy Research Institute, Daejeon, Korea
  • Jang-Lyul Kim Korea Atomic Energy Research Institute, Daejeon, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      0개의 논문이 장바구니에 담겼습니다.