원문정보
A Study on the development of Explosion-proof type's the terminal box of the ventilator with the control of wind volume and operating time
초록
영어
This thesis is about the study of inverter terminal boxes in a explosion proof type exhaust fan that can control wind volume and operating time. In Korea, there is no ventilator to adjust the amount of wind and operating time when working in poor conditions. The purpose of the project is to create a explosion terminal box that can control the operating time and wind speed of a suitable explosion ventilator in hazardous environments. The two explosion-proof switches allow the operation time to be driven 1 hour, 3 hours and continuous time, and the speed of the induction motor rotation was set in 3 stages at 2000 rpm, 2600 rpm and 3000 rpm to control the volume. The tested motor used a half-horsepower barrier three-phase induction motor and a full-bridge inverter to set the desired flow rate and operating time.
한국어
본 논문은 풍량 및 운전시간을 제어할 수 있는 방폭 타입 배풍기의 인버터 단자함 연구에 관한 것이다. 국내에서는 열악한 환경에서 작업 시에 풍량 및 운전 시간을 조정할 수 있는 배풍기가 없는 실정이다. 유해가스 및 폭발 위험성이 있는 환경에 적정한 방폭 배풍기의 운전 시간과 풍량을 제어할 수 있는 방폭 단자함을 제작하는 것이 목적이다. 2개의 방폭형 스위치를 사용하여 운전시간을 1 시간, 3 시간, 그리고 연속 시간으로 운전할 수 있도록 하였고, 유도전동기 회전 속도는 2000rpm, 2600rpm, 그리고 3000rpm으로 3 단계로 설정하여 풍량 제어하였다. 실험한 모터는 1/2 마력 3상 유도전동기 사용하였으며 풀 브리지 인버터를 제작하여 원하는 풍량과 운전시간 설정할 수 있도록 연구하였다.
목차
Abstract
1. 서론
2. 방폭 단자함
2.1 방폭 단자함 설계 조건
2.2 방폭형 전동기 구조
2.3 배풍기 속도 및 풍량 제어
3. 시험평가
3.1 방폭 배풍기 풍량 및 속도 평가
3.2 방폭형 인버터 단자함 시험 평가
4. 결론
REFERENCES