In Situ Gamma-ray Spectrometry Using an LaBr3(Ce) Scintillation Detector

원문정보

Young-Yong Ji, Taehyung Lim, Wanno Lee

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Background: A variety of inorganic scintillators have been developed and improved for use in radiation detection and measurement, and in situ gamma-ray spectrometry in the environment remains an important area in nuclear safety. In order to verify the feasibility of promising scintillators in an actual environment, a performance test is necessary to identify gamma-ray peaks and calculate the radioactivity from their net count rates in peaks. Materials and Methods: Among commercially available scintillators, LaBr3(Ce) scintillators have so far shown the highest energy resolution when detecting and identifying gamma-rays. However, the intrinsic background of this scintillator type affects efficient application to the environment with a relatively low count rate. An algorithm to subtract the intrinsic background was consequently developed, and the in situ calibration factor at 1 m above ground level was calculated from Monte Carlo simulation in order to determine the radioactivity from the measured net count rate. Results and Discussion: The radioactivity of six natural radionuclides in the environment was evaluated from in situ gamma-ray spectrometry using an LaBr3(Ce) detector. The results were then compared with those of a portable high purity Ge (HPGe) detector with in situ object counting system (ISOCS) software at the same sites. In addition, the radioactive cesium in the ground of Jeju Island, South Korea, was determined with the same assumption of the source distribution between measurements using two detectors. Conclusion: Good agreement between both detectors was achieved in the in situ gamma-ray spectrometry of natural as well as artificial radionuclides in the ground. This means that an LaBr3(Ce) detector can produce reliable and stable results of radioactivity in the ground from the measured energy spectrum of incident gamma-rays at 1 m above the ground.

목차

ABSTRACT
 Introduction
  1. Theory
 Materials and Methods
  1. The LaBr3(Ce) detector
  2. In situ calibration factor
  3. Method of the experimental verification
 Results and Discussion
  1. The determination of in situ calibration factors
  2. Natural radionuclides in the ground
  3. The determination of deposited radionuclides
 Conclusion
 Acknowledgements
 References

저자정보

  • Young-Yong Ji Korea Atomic Energy Research Institute, Daejeon, Korea
  • Taehyung Lim SI Detection Co. Ltd., Daejeon, Korea
  • Wanno Lee Korea Atomic Energy Research Institute, Daejeon, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      0개의 논문이 장바구니에 담겼습니다.