영어

Recently, the laundries are becoming magnification and automation, with changing the lifestyle of modern people, and the laundry fires continue to occur annually. In particular, the laundry explosion fires by oil vapor can cause a lot of casualties and property damage because of creating a shock wave as well as flame. Most of them take place by the reaction between ignition sources such as static electricity(friction), spark(short circuit), motor overheating and oil vapor of dry cleaning solvent in dry machine. Among them, static electricity is the most common ignition source in laundry explosion fires, but few systematically studied the explosion condition by static electricity. First, we have verified the explosion characteristics for dry cleaning solvents by investigating the qualitative analysis(GC-MS), flash point, explosive range, hazard(MSDS). This test has measured the minimum ignition energy of static electricity depending on the internal temperature, current, the distance between electrodes. As a result, the minimum ignition energy of static electricity has increased by decreasing internal temperature, current and extending the distance between electrodes.

목차

Abstract
 1. 서론
  1.1 연구배경 및 목적
  1.2 화재발생 통계
  1.3 세탁소 폭발화재 사례
 2. 본론
  2.1 가연성 용매의 폭발 위험성
  2.2 가연성 용매의 화학적 폭발 메커니즘
  2.3 드라이클리닝 시스템
  2.4 드라이클리닝 용매의 폭발위험성
  2.5 폭발위험성 평가실험
 3. 결론
 감사의 글
 참고문헌

저자정보

  • 김순영 Soon Young Kim. 인천공단소방서
  • 장필순 Pil Soon Jang. 인천공단소방서

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,900원

      0개의 논문이 장바구니에 담겼습니다.