earticle

논문검색

Discrepancies in Dose-volume Histograms Generated from Different Treatment Planning Systems

초록

영어

Background: We analyzed changes in the doses, structure volumes, and dose-volume histograms (DVHs) when data were transferred from one commercial treatment planning system (TPS) to another commercial TPS. Materials and Methods: A total of 22 volumetric modulated arc therapy (VMAT) plans for nasopharyngeal cancer were generated with the Eclipse system using 6-MV photon beams. The computed tomography (CT) images, dose distributions, and structure information, including the planning target volume (PTV) and organs at risk (OARs), were transferred from the Eclipse to the MRIdian system in digital imaging and communications in medicine (DICOM) format. Thereafter, DVHs of the OARs and PTVs were generated in the MRIdian system. The structure volumes, dose distributions, and DVHs were compared between the MRIdian and Eclipse systems. Results and Discussion: The dose differences between the two systems were negligible (average matching ratio for every voxel with a 0.1% dose difference criterion = 100.0 ± 0.0%). However, the structure volumes significantly differed between the MRIdian and Eclipse systems (volume differences of 743.21 ± 461.91% for the optic chiasm and 8.98 ± 1.98% for the PTV). Compared to the Eclipse system, the MRIdian system generally overestimated the structure volumes (all, p < 0.001). The DVHs that were plotted using the relative structure volumes exhibited small differences between the MRIdian and Eclipse systems. In contrast, the DVHs that were plotted using the absolute structure volumes showed large differences between the two TPSs. Conclusion: DVH interpretation between two TPSs should be performed using DVHs plotted with the absolute dose and absolute volume, rather than the relative values.

목차

ABSTRACT
 Introduction
 Materials and Methods
  1. Patient data and planning
  2. Data transfer from the Eclipse to the MRIdian system
  3. Evaluation of doses, volumes, and dose-volume histograms
 Results and Discussion
  1. Dose differences
  2. Volume differences
  3. Dose-volume histogram differences
 Conclusion
 Acknowledgements
 References

저자정보

  • Jung-in Kim Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea
  • Ji Hye Han Department of Physics, Ewha Womans University, Seoul, Korea
  • Chang Heon Choi Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea
  • Hyun Joon An Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea
  • Hong-Gyun Wu Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea, Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Korea
  • Jong Min Park Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea, Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea, Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea, Robotics Research Laboratory for Extreme Environments, Advanced Institutes of Convergence Technology, Suwon, Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      0개의 논문이 장바구니에 담겼습니다.