원문정보
A Study on the Heat Transfer Analysis of the Rear Hot Wire using Taguchi Design Method
초록
영어
A cold chamber experiment was made to continuously record defrosting process of the frosted window. To achieve this purpose, first a warm-chamber experiment(23℃) were performed to measure inner and outer surface temperature of the rear window as functions of both time and position. In this study, mutual relation of each experimental condition was derived through minimum number of experiment using Taguchi Design method and ANOVA recently used in the various fields. The optimal temperature distribution using Taguchi technique is 120 sec, heat wire size is 1.0mm, and heat wire spacing is 25mm.
목차
1. 서론
2. 이론적 배경
2.1 열절달 이론
2.2 실험 계획법
3. 실험장치 및 조건
4. 실험 결과
5. 결론
References