원문정보
초록
영어
Energy saving in household refrigerators becomes more important as the usage of household refrigerators have been increasing every year. Since a compressor in the refrigerator consumes more than 80% of its total energy, it is necessary to reduce the energy consumption of the compressor. In this paper, the convective heat transfer coefficients on the compressor housing for both natural convection and forced convection were measured. Then, the effect of convective heat transfer coefficient on the power consumption of a refrigerator was investigated using a thermal management analysis. The results showed that convective heat transfer coefficient for forced convection is higher by 7.8 W/m 2 K compared to the natural convection. In addition, through the thermal management analysis, it was found that the increase in convective heat transfer coefficient reduces the refrigerator power by about 4.8% improving EER by 0.9%.
목차
1. 서론
2. 실험 및 수치해석방법
2.1 실험방법
2.2 수치해석방법
3. 결과 및 토론
3.1 대류열전달계수 측정
3.2 냉장고 소비전력 측정
3.3 대류열전달계수에 따른 압축기성능 수치해석
4. 결론
후기
References