earticle

논문검색

실험논문(원저논문)

치과용 스캐너의 광원에 따른 디지털 모형의 정확도 비교연구

원문정보

Comparative study of accuracy of digitized model fabricated by difference optical source of non-contact 3D dental scanner

김재홍, 이정수, 심정식

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by difference optical source of non-contact 3D dental scanner. Methods: A master model with the prepared upper full arch tooth was used. Stone model(N=10) were produced from master model, and on the other hands, digital models were made with the 3D dental scanner(Blue, white, red optical source). The linear distance between the reference points were measured and analyzed on the Delcam CopycadⓇ graphic software. The results were statistically analyzed using the one-way ANOVA and Tukey’s HSD test(α=0.05). Results: There were considerable differences in mean values between optical source within each color(blue, white, red), and this difference was not statistically significant(p>0.05). Conclusion : Three different color of dental scanner optical source showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

목차

[Abstract]
 Ⅰ. 서론
 Ⅱ. 연구 방법
  1. 실험 재료
  2. 실험 방법
  3. 통계분석
 Ⅲ. 결과
 Ⅳ. 고찰
 Ⅴ. 결론
 REFERENCES

저자정보

  • 김재홍 Jae-Hong Kim. 동남보건대학교 치기공과
  • 이정수 Jung-Soo Lee. 신구대학교 치기공과
  • 심정식 Jeong-Seok Shim. 신구대학교 치기공과

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.