원문정보
A Study on the Area of Fire Origin Determination Using Video Recorder
초록
영어
In this study, we realized a determination method for the area of fire origin by using an angle between object and its shadow which is projected on the floor from the CCTV visual display not directly taken fire origin. This method use the transformation process that the distortion calibration and calibrated display of CCTV are converted to top view display. The area of fire origin is determined by the distance between and object and a fire origin. To predict a fire origin through transformation of CCTV visual display expand the application of CCTV and the scope of evidence. Because of no additional conditions, this method can be recognized as being more valuable than traditional ways.
목차
1. 서론
2. 이론적 배경
2.1 빛과 그림자의 생성
2.2. 카메라 캘리브레이션(camera calibration)
2.3 영상의 왜곡과 왜곡보정
2.4 왜곡보정 영상의 Top View 영상으로의 변환
3. 실험 및 결과 고찰
3.1 실험조건
3.2 화염의 크기 및 그림자 형성이 가능한 거리
3.3 삼각함수와 그림자 인상을 이용한 발화지점 추정
3.4 CCTV 왜곡 영상의 보정 및 TOP VIEW 영상 변환
4. 결론
참고문헌