영어

In this paper, It look for solution of a climate change and the warming. The solution reduce CO2. The method is carbon dioxide emissions. and then it is ETS(Emissions Trading Scheme). At IDC I research an objective evaluation method for reducing the CO2 . I study PUE(Power Usage Efficiency) and TPUE(Total Power Usage Efficiency). We’ve discussed how to measure total facility power. The short summary is it must be measured prior to all UPS and power conditioning at medium voltage. If high voltage is delivered directly to your facility, you should measure after the first step down transformer. If your facility is delivered low voltage, then ask your power supplier whether it be the utility, the colo-facility owner, or your companies infrastructure group, the efficiency of the medium to low step down transformer at your average load. Add this value in mathematically. This is not perfect but it better than where we are right now when we look at a PUE. Please consider helping to evangelize tPUE and use tPUE. And, for you folks designing and building commercial servers, if you can help by measuring the Productive IT Equipment Power for one or more of your SKUs, I would love to publish your results. If you can supply Productive IT Equipment Power measurement for one of your newer servers, I’ll publish it here with a picture of the server. The Green Grid proposed the use of Power Usage Effectiveness (PUE) and its reciprocal, Datacenter Efficiency (DCE) metrics, which enable datacenter operators to quickly estimate the energy efficiency of their datacenters, compare the results against other datacenters, and determine if any energy efficiency improvements need to be made. Since then, PUE has received broad adoption in the industry, but DCE has had limited success due to the misconception of what data center efficiency really means. As a result, this paper reaffirms the use of PUE but redefines its reciprocal as datacenter infrastructure effi ciency (DCiE). This refinement will avoid much of the confusion around DCE and will now be called DCiE. In the long term, The Green Grid is developing metrics to measure data center productivity as well as efficiency metrics for all major power-consuming subsystems in the datacenter. To promote these metrics and drive greater datacenter energy efficiency for businesses around the world, The Green Grid will publish future white papers that provide detailed guidance on using these metrics. We will also continue to collaborate with organisations such as the EPA, ECMA and Climate Savers that promote a similar goal and vision. They are not enough. PUE has the problems that evaluate the power saving performance of only IT machinery. PUE(Power Usage Effectiveness), DCE(Datacenter Efficiency), DCiE(Data Center Infra Efficiency), DCPE(Datacenter Performance Efficiency), DPPE(Datacenter Performance Per Energy), etc has some problems. DUE solves the problems. DUE contain natural power facility. It measures the power saving performance of IT machinery and tools. and It measures natural energy use. but, DUE is case of the CO2 measure in IDC. From now on, You must study it. Development to the general evaluation index is demanded.

한국어

본 논문에서는 요사이 대두되고 있는 환경 변화에 따른 기후 변화 및 온난화의 문제의 주범 인 CO2 의 감축 문제를 해결하기위한 방법론에서 등장한 탄소배출권 대하여 알아보며, 배출권거래에 따 라 탄소 배출권 거래시장이 형성 되었고, 이러한 현상은 각국이 온실가스 즉 CO2 의 감축과 각국의 성장 이 함께 움직이는 현상을 보이고 있다. 이렇게 국가 간의 CO2 발생이 국가 성장에 영향력을 나타내기에 국가 간에는 자국에서 발생되는 CO2 양에 대한 객관적이고 정확한 평가가 중요한 이슈로 떠오르고 있 다. 그리고 CO2 양에 대한 평가가 국가 간의 이해 및 분쟁의 소지로 발전되어가는 현상을 보이고 있다. 이러한 각국의 온실가스 감축평가에 대한 이해관계를 중재 할 수 있는 평가 규정이 현실화되기 위하여 서는 각국에서 이해하고 납득 할 수 있는 정확하고, 객관적인 평가지표의 개발이 시급한 실정이다. 즉 각국에 합당한 온실 가스 감축의 양을 결정하고, 감축결과를 정확하고, 객관성 있게 평가하는 평가지표 가 요구된다. 이러한 평가지표를 통해 각국의 온실가스 감축이 객관화 될 수 있을 것이다. 이러한 이유 로 탄소 배출권에 대한 거래의 장소인 탄소 시장과 탄소배출권의 주목표인 CO2 의 감축에 대한 객관적 평가방법에 대하여 IDC를 중심으로 조사하여, 가장 합리적이고 최적화의 평가 지표의 개발을 위한 탐색 적 연구를 시도했다. IDC를 중심으로 객관적으로 평가할 수 있는 평가지표로는 그린 그리드(Green Grid)가 발표한 일반적으로 사용 하고 있는 PUE(Power Usage Effectiveness), PUE 역의 지표인 DCE(Datacenter Efficiency), DCE의 백분율의 형태로 변환한 지표인 DCiE(Data Center Infra Efficiency), 전체에너지를 수행능력으로 보완한 지표인 DCPE(Datacenter Performance Efficiency), DPPE(Datacenter Performance Per Energy)에 대하여 특징 및 보완점을 조사 연구하여, 이 지표들의 문제점을 제기하고 대안으로 DUE를 제안 하였다. DUE는 PUE의 데이터센터의 IT 기기이외의 에너지 절감 성능은 평가할 수가 없다는 문제점의 대안과 IT 기기의 에너지절감 성능에 태양광발전이나 풍력 발전 등의 자연에너지를 얼마만큼 활용하고 있는지 등도 평가할 수 있는 새로운 평가지표로 구성되어있 다. 하지만 본 논문에서 제시한 평가지표는 IDC를 중심으로 개선되어진 평가지표인 만큼 앞으로 연구를 통하여 산업 전반에 걸친 일반적인 평가지표로의 개발이 요구된다.

목차

국문요약
 Ⅰ. 서론
 Ⅱ. 탄소배출권의 개념 정의 및 각국의 탄소 시장의 추진현황
  2.1 탄소배출권의 개념 정의
  2.2 탄소시장의 도입배경
  2.3 세계 탄소 시장 현황
 Ⅲ. 기존의 각국의 평가지표와 국제 표준화 지표 개발
  3.1 국제표준화 평가지표개발의 필요성
  3.2 각국의 평가지표 및 문제점
  3.3 국제 표준화지표의 방안
 Ⅳ. 결론
 참고문헌(reference)
 Abstract

저자정보

  • 심상천 Sang-Chun Sim. 가천대학교 경상대학 경영학과 교수