원문정보
Advanced Treatment of Artificial Urban Wastewater with Up-down Flow Complete Mix Process
초록
영어
The up-down flow complete mix process was operated for 60 days to evaluate the removal efficiencies of COD, T-N and T-P with regards on HRT, internal recycle (IR) and sludge retention time (SRT), respectively. From tests under various hydraulic retention time (HRT) conditions, COD removal efficiency over 90% was obtained at HRT 2.4 h, which is higher than that of 78~90% at 4.9 h. T-N removal efficiency showed over 80% at HRT 2.4 h. T-P removal efficiency showed better result at HRT 4.9 h. From tests under various IR conditions, COD removal efficiency above 90% with IR 1Q showed better than that with IR 2Q. T-N removal efficiency showed gradual increase over 80% at IR 1Q. T-P removal efficiency showed 40~85% with IR 2Q. From tests under various SRT conditions, COD removal efficiency showed over 95% at SRT 10 days. T-N removal efficiency showed over 85% at SRT 10 days, which is better than that at SRT 20 days. T-P removal efficiency showed around 60% at SRT 10 days, which was better result compared at SRT 20 days.
한국어
COD, T-N 및 인 제거효율을 평가하기 위하여 수리학적 체류시간(HRT), 내부반송율 (IR) 및 고형물체류시간 (SRT)을 변화시키며 60일 동안 상·하향류 완전혼합 장치를 운전하였다. HRT 변화실험에서 COD 제거효율은 HRT 2.4 h에서 90% 이상의 제거효율을 보임으로써 HRT 4.9 h의 78~90%의 제거효율보다 높게 나타났다. T-N 제거효율에서는 HRT 2.4 h에서 80% 이상의 더 좋은 효율을 나타내었다. 인 제거율은 HRT 4.9 h에서 더 높은 제거효율 결과를 얻었다. 내부반송 율(IR) 실험에서는 COD 제거효율이 IR 1Q에서 90% 이상의 제거효율로 IR 2Q 보다 더 높게 나타났다. T-N 제거효율에 서는 IR 1Q일 때 점차로 제거효율이 상승하여 80% 이상의 결과를 나타내었다. 인 제거율은 IR 2Q에서 40~85%의 결과 를 나타내었다. 고형물 체류시간(SRT) 실험에서는 COD 제거율이 SRT 10일에서는 95% 이상의 제거율을 보였다. T-N 제거효율에서는 SRT 10일 일때 85% 이상의 제거효율을 보여서 SRT 20일 일때보다 더 높은 제거효율을 보였다. 인 제 거율은 SRT 10일에서는 60% 전후의 결과로 SRT 20일에서 보다 더 높은 제거효율을 나타내었다.
목차
요약문
I. 서론
II. 실험방법 및 재료
1. 유입 인공 도시하수
2. 실험장치
III. 실험결과 및 고찰
1. 수리학적 체류시간 (HRT) 변화에 따른 영향
2. 내부반송율(Internal recycle ratio) 변화에 따른 영향
3. 고형물 체류시간(SRT) 변화에 따른 영향
IV. 결론
사사
References