원문정보
Characteristics and TOC Effluent Standard of Organic Wastewater discharged from Basic Compound Manufacturer in Petrochemicals
초록
영어
In this study, CODMn, CODCr and TOC were measured for each process of the wastewater treatment plant of basic compound manufacturer in petrochemicals. Also their oxidation rates for organics and correlation rates to each other were analyzed. The analysis results showed that TOC was more appropriate than CODMn and CODCr as organic indicator for the manufacturer aimed in this study. Also the consistency of relative oxidation and correlation rates among CODMn, CODCr and TOC in the effluent were then obvious, and the CODMn/TOC rate was 1.5. Thus it can be appropriate that the permissible effluent standard for TOC is established by applying the CODMn/TOC rate of 1.5 and converting CODMn into TOC. For example, the current CODMn standard of 90 mg/L or less can be replaced by the recommended TOC standard of 60 mg/L or less for basic compound manufacturer’s wastewater in petrochemicals.
한국어
본 연구에서는 석유화학계 기초화합물 제조시설을 대상으로 최종 배출수뿐 아니라 공정별 CODMn, CODCr, TOC 농도 를 측정하고 이들 항목들 간의 산화율 비교 및 상관성을 조사하였다. 그 산화율 조사결과는 이 제조시설 폐수의 경우에 유기물 지표로 CODMn과 CODCr의 사용이 부적합하고 TOC의 사용이 타당한 것으로 나타났다. 그러나 폐수처리장 방류 수의 경우에는 CODMn, CODCr, TOC 측정값들 간의 상관성과 상대비의 일관성이 명확히 나타났고 CODMn/TOC의 비는 1.5였다. 이 비를 사용하여 현재 방류수 CODMn 배출허용기준이 90 mg/L 이하인 지역을 대상으로 하면 이때 TOC 배출 허용기준은 60 mg/L 이하로 환산될 수 있고, 이를 석유화학계 기초화합물 제조시설 폐수처리장 방류수의 해당 CODMn 기준 대신에 TOC 기준(안)으로 설정할 수 있다.
목차
요약문
I. 서론
II. 재료 및 방법
1. 조사대상
2. 조사시기 및 방법
III. 결과 및 고찰
1. 폐수처리 공정별 수질 특성
2. 폐수처리 공정별 유기물질 지표간의 상관성 분석
3. 폐수처리 공정별 유기물질의 산화율과 지표간 상대비
IV. 결론
감사의 글
References