원문정보
Pilot Test for Enhancing Anaerobic Digestion by Sludge Thermo-solubilization
초록
영어
Pilot scale system was used to test sludge thermo-solubilization. Without using energy for wet oxidation condition (250℃, 40 atm, oxidant addition), optimized operating conditions were attained at 200℃, 20 atm, RT=60 min and total SS removal efficiency of 60% due to the destruction of microbial cell wall in the sludge was achieved under thermosolubilization condition (175~200℃, 18~20 atm, no addition of oxidant). More than 20% of molecular weight conversion rate (TVFA/SCOD) was obtained for anaerobic digestion through transition of a higher molecular matter into lower one. Sludge thermo-solubilization for anaerobic digestion pretreatment enabled the improvement of OLR (organic loading rate) and the establishment of higher biogas production system based on the increased anaerobic digestion rate.
한국어
슬러지 열가용화 시험을 위하여 파일럿 장치를 사용하였다. 슬러지의 습식산화 조건(250℃ 이상, 40 atm, 산화제 주입)에 필요한 높은 에너지를 사용하지 않고, 열가용화 조건(175~200℃, 18~20 atm, 산화제 주입 없음)을 이용하여 200℃, 20 atm, RT=60 min 에서 최적의 운전조건을 나타냈으며, 가용화에 의한 슬러지 내 미생물의 세포벽을 파괴함으로써 전체 SS제거율 60%를 달성하였다. 또한 가용화된 고분자 물질을 혐기소화에 유용하게 이용할 수 있도록 저분자 물질로 전환시켜 전환율(TVFA/SCOD)을 평가한 결과 20% 이상의 결과를 얻었다. 슬러지의 열가용화 전처리를 통하여 혐기소화조에서 OLR(Organic Loading Rate)를 향상시킬수 있었고, 높아진 혐기소화율을 기초로 가스 발생량도 월등한 슬러지 열가용화 시스템의 구축이 가능하였다.
목차
요약문
I. 서론
II. 실험방법 및 재료
1. 대상하수 슬러지
2. 실험장치
3. 분석방법
III. 결과 및 고찰
1. 액상 유기물질 분해실험
2. 열가용화 운전조건 실험
3. 최적 운전조건에 따른 운전항목별 변화추이
4. 슬러지 농도에 따른 열가용화 시험
5. 슬러지 가용화액 혐기소화 시험
IV. 결론
사사
References