원문정보
초록
영어
In this study, a hot water pipe and a blowing fan were combined for developing zone heating technology for cherry tomato. The concept of this system was that hot air was firstly made by hot water pipe in one layer plastic duct and then a blowing fan made the hot air formed in a duct discharge through a duct hole to a shoot apex or a flower cluster which was temperature-sensitive part of cherry tomato. This system mainly consisted of hot water boiler, thermal tank, heat radiation plastic duct with the function of moving up and down electrically depending on the height of shoot apex. Developed system was applied to the cherry tomato greenhouse located in Jangam Chungcheongnamdo from Dec. 28, 2015 to Feb. 16, 2016 and compared with conventional entire space heating system of cherry tomato greenhouse and looked into cumulative yield for the estimate of growing state and energy saving rate from the conventional consumed energy. The result showed that cumulative yield was 3% higher and consumed energy was 32% lower than those of control greenhouse. The average temperature of shoot apex zone was 0.4~1.1℃ higher and the average relative humidity of shoot apex zone was 2,2~2.3% lower than those of entire space during night time in a shoot apex zone heating greenhouse and the average temperature of shoot apex zone was 0.7~1.4℃ lower and the relative humidity of shoot apex zone was 2.9~8.3% higher than those of entire space during night time in a entire space heating greenhouse.
목차
1. 서론
2. 재료 및 방법
2.1 토마토 생장점 부분 난방 시스템 구조개선
2.2 생장점 추종형 부분 난방 덕트 방열량 측정
2.3 토마토 부분 난방 현장 시험
3. 결과 및 고찰
3.1 온도 조절 효과
3.2 습도 조절 효과
3.3 수확량 비교 및 에너지 절감 효과
4. 결론
후기
References
저자정보
참고문헌
- 1Rural Development Administration(RDA), “Protected Horticulture Energy Saving Guide Book for Overcoming High Oil Price,” Sangrok press, p. 11, 2008
- 2Ministry of Agriculture, Food and Rural Affairs (MAFRA), “Greenhouse Status for the vegetable grown in Facilities and the vegetable production in 2014,” Hanra planning, pp. 112-113, 2015
- 3Local Heating Effect of Phalaenopsis Cultivation Beds using Hot Water Padearticle 원문 이동
- 4Effect of Root Zone Temperature on Root and Shoot Growth of Strawberry네이버 원문 이동
- 5Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe네이버 원문 이동
- 6J. P. Moon, G. C. Kang, J. K. Kwon, Y. Paek, T. S. Lee, S. S. Oh and M. H. Nam, “Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe,” Journal of the Korean Society of Agricultural Engineers Vol. 58, No. 5, pp. 69-77, 2016
- 7Effect of Growing Part Following Local Heating for Cherry Tomato on Temperature Distribution of Crop and Fuel Consumption네이버 원문 이동
- 8I. H. Cho, Y. H. Woo, H. Nishina and Y. Hashimoto, “Studies on Zone Cooling of Greenhouse in Daytime in Summer and Occurrence of Blossom-End Rot in Tomato Plants,” Journal of Biological Production Facilities & Environmental Control, Vol. 3, No. 1, pp. 36-41, 1994
- 9Study on Hybrid Optimal Operation Technology of Air Source Heat Pump and Diesel Heaterearticle 원문 이동