원문정보
A Study on the Design for Optimization of Cylinder Body at Injection Molding Machine
초록
영어
An injection unit is the important part which guide the melted resine into the mold. Once injection molding is performed, there will be a pressure of 33 MPa built up inside of injection cylinder body. It was confirmed that the crack occurs by internal stress on the 9 mm material when the machine is used for long time. Because the cylinder rod has material thickness of 9~12 mm during manufacturing process on the cylinder body, there would be 3 mm thickness differences. In this experiment, IDEAS, a computer aided structure analysis software, is used to present the optimized design condition. Insert rod with inner diameter of 9 mm was set as a normal and vary 3 mm in x, y axis direction. When the internal pressure of 33 MPa occurs at the injection unit, fix the x and y direction and find out the stress acting only in z axis. It was confirmed that the stress of 45~82 N/mm 2 was built up when the left of cylinder body had been set 9 mm by using a structure analysis. Also, it has been verified the thickness of the material on the left need to be greater and equal than 12 mm to prevent a material crack by an internal stress.
목차
1. 서론
2. 소재결함 분석
3. 인젝션 실린더 바디 설계
4. 결과 및 고찰
5. 결론
References