earticle

논문검색

Numerical estimation on balance coefficients of central difference averaging method for quench detection of the KSTAR PF coils

초록

영어

A quench detection system of KSTAR Poloidal Field (PF) coils is inevitable for stable operation because normal zone generates overheating during quench occurrence. Recently, new voltage quench detection method, combination of Central Difference Averaging (CDA) and Mutual Inductance Compensation (MIK) for compensating mutual inductive voltage more effectively than conventional voltage detection method, has been suggested and studied. For better performance of mutual induction cancellation by adjacent coils of CDA+MIK method for KSTAR coil system, balance coefficients of CDA must be estimated and adjusted preferentially. In this paper, the balance coefficients of CDA for KSTAR PF coils were numerically estimated. The estimated result was adopted and tested by using simulation. The CDA method adopting balance coefficients effectively eliminated mutual inductive voltage, and also it is expected to improve performance of CDA+MIK method for quench detection of KSTAR PF coils.

목차

Abstract
 1. INTRODUCTION
 2. NUMERICAL ESTIMATION ON CDA
  2.1. Simple CDA
  2.2. Balance coefficients of CDA estimation
 3. SIMULATION RESULTS
  3.1. CDA
  3.2. CDA+MIK
 4. CONCLUSION
 REFERENCES

저자정보

  • Jinsub Kim Yonsei University, Seoul, Korea, National Fusion Research Institute(NFRI), Daejeon, Rep. of Korea
  • Seok Chan An Yonsei University, Seoul, Korea, National Fusion Research Institute(NFRI), Daejeon, Rep. of Korea
  • Tae Kuk Ko Yonsei University, Seoul, Korea
  • Yong Chu National Fusion Research Institute(NFRI), Daejeon, Rep. of Korea