원문정보
Observation of Shape after sinter of Dental Co-Cr sinter metal
초록
영어
Purpose: Currently advanced in Dental CAD/CAM technology increase a use of Co-Cr sinter metal block at Dental CAD/CAM part traditionally it has been being used with metal casting method. There is an advantage that can leave out a step of investment and casting as well as reducing a working time to compare with conventional casting method in a dry milling. Methods: In this research, compare a deformation of before and after sinter result of Co-Cr sinter metal block. Design a specimen figure by 3D CAD software and transformed it to a STL file can be used at Dental CAD/CAM. With a transformed STL file, milled a Co-Cr sinter metal specimen by using a Dental CAD/CAM dry milling machine. It arrived at the following conclusions after measuring an outer form and thickness of a machined specimen and then after sinter measure it again in a way of before sinter measurement method. Results: It is confirmed that there is no error while a 3D design figure specimen is transformed to a Dental CAD data. It is observed that there is no error at Co-Cr sinter metal specimen which consider a length of single coping and bridge. Conclusion: It is observed that there is no deformation at a specimen of AS05 and AB05 are made of 0,5mm thickness. On the other hand, the out of range of deformation is observed at a specimen of AS10 and AB10 which are made of 1mm thickness.
목차
Ⅰ. 서론
Ⅱ. 연구 방법
1. 실험 재료
2. 3차원 시편 설계
3. 시편 가공
4. 3차원 시편 외형측정 실험
5. 소결 전·후 시편 외형측정 실험
Ⅲ. 결과
1. 3차원 시편 외형측정
2. 소결 전·후 시편 외형측정
Ⅳ. 고찰
Ⅴ. 결론
REFERENCES