초록

영어

On the basis for analysis of the factors affecting fire occurrence process and the fire accident in connection with a fire accident Loxoprofen-Acid Powder as recently occurred, it was tested in the fire accident caused the Loxoprofen-Acid powder through a physical hazard testing and evaluation of fire-based figures. To survey causes, the particle size and moisture content of the primary evaluation of the measurement items in the dust explosion characteristics were evaluated and the minimum ignition energy measurement were tested on a similar sample. If the electrostatic discharge energy through the minimum ignition energy measurement test is greater than the minimum ignition energy of the Loxoprofen-Acid powder and acetone, it was found that the fire and explosion may occur.

한국어

검토에서는 최근 발생한 록소프로펜산 분말의 화재사고와 관련하여 화재사고 발 생과정 및 화재사고 발생에 영향을 주는 요인들에 대한 분석을 토대로, 화재사고 기인 물의 물리적 위험성 시험·평가를 통한 록소프로펜산 분말의 화재사고 발생원인에 대 하여 검토하였다. 발생원인 검토를 위하여 유사시료의 최소 점화에너지의 측정과 분진 폭발 특성의 기본평가 항목인 입도와 수분함량 평가를 실시하였다. 최소 점화에너지 측정실험을 통하여 정전기 방전 에너지가 아세톤 및 록소프로펜산 분말의 최소 점화 에너지 보다 큰 경우 화재·폭발이 발생할 수 있음을 알 수 있었다.

목차

초록
 Abstract
 1. 서론
 2. 본론
  2.1 발생개요
  2.2 화재사고 발생에 영향을 주는 추정요인들(2~5)
  2.3 최소 점화에너지 측정(6)
 3. 결론