원문정보
초록
영어
In structured light 3D measurement field, when the object has smooth surface, it can form a highlight area due to the specular reflection, and the distortion of the object will make a large measurement error. In order to solve this problem, this paper use seven steps sine-phase shift combined with linear diffuser to remove highlight. Firstly, the principle of removing specular with diffuser is analyzed, then the overall design of the system is introduced, which includes 3D reconstruction and system calibration method. Finally the reconstructed experiments are carried out with ceramic plate. Experimental results show that the proposed method can significantly reduce the highlights area of reconstructed image compared with the highlights area without diffuser. The diffuser can obviously inhibited by highlights, although it can not completely remove the highlights, it plays a very important role in reconstructing specular object with more accurate and better quality.
목차
1. Introduction
2. The Principal of Removing Highlights with Diffuser
3. System Introduction
3.1. System Design
3.2. Camera Calibration
3.3. Projector Calibration
4. Experiment
5. Conclusions
Acknowledgments
References