원문정보
Evaluation of internal adaptation of PMMA 3-unit bridge manufactured by 5-axis milling machine
초록
영어
Purpose: The purpose of this study was to assess the internal fitness of the PMMA 3-unit bridge that was fabricated with 5-axis milling machine and to verify the clinically allowable values. Methods: For fabrication of the crown bridge in this study, 25-27 abutment teeth were used. The prepare abutment teeth were scanned with a scanner and 3-unit bridge was designed by using design software. Upon the completion of the design, the 3-unit bridge was fabricated by using a PMMA block with 5-axis milling machine. The internal surface of the fabricated 3-unit bridge was scanned by using a scanner and the difference between the 3-unit bridge and the abutment teeth was assessed by merging them together. Results: RMS±SD values for PRE group, MOL group, and BRI group were 51.2±18.2, 44.8±10.0, and 52.1±8.3㎛, respectively. The mean of the PRE group was bigger than that of the MOL and BRI group; however, statistically significant difference was not found (p>0.05). Conclusion: The PMMA 3-unit bridge that was fabricated with 5-axis milling machine presented stable internal values for each crown and overall internal values were within the range of clinically allowable values.
목차
Ⅰ. 서론
Ⅱ. 연구 방법
1. 지대치 제작 및 스캔
2. 디자인 및 밀링
3. 3차원 측정
4. 통계분석
Ⅲ. 결과
Ⅳ. 고 찰
Ⅴ. 결론
REFERENCES