A Study on Freezing Assessment of the Water in the Z-Trap of Sewage Bay

Changwoo Lee, Seungju Oh

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

This study clarifies the simulation on freezing of remaining water in the Z-trap set up in the PVC sewage bay to control malodor. It made use of commercial FEM LAB program(ver. 3.2) well known as a solution of the problems arising in the flow of various fluid, heat transfer and mass transfer. Simulation results under the temperature –20℃ outwards show that the water in the Z-trap set up in the sewage bay to control malodor freeze in the 60cm under the ground level after 14 days in the wet ground, and after 17 days in the regular ground. On the other hand, if the soil is dry even after the 42 days does not go down below freezing. Therefore, the water in the Z-trap was confirmed that it does not freeze.

한국어

본 연구에서는 PVC 오수받이를 대상으로 상용 프로그램인 FEM LAB(ver. 3.2)을 이용하 여 여러 시공 환경조건에서 오수받이 내부에 설치된 악취방지용 Z형 트랩 내부에 잔류하고 있는 물의 겨울철 동결여부를 평가하였다. 시뮬레이션 결과 외부온도 –20℃가 42일간 지속되더라도 토양이 건조한 상태라면 Z형 트랩에 남아 있는 물이 동결되지 않음을 알 수 있다. 토양이 습윤 상태일 경우 약 14일 정 도, 토양이 일반상태의 경우 약 17일 정도가 지나면 Z형 트랩이 위치한 지면으로부터 60cm 지점이 Z형 트랩 내에 동결될 가능성이 있으나, 토양이 건조한 상태에 있을 경우에는 42일 이 지나도 지면으로부터 60cm 지점은 영상의 온도를 유지하는 것으로 보아 Z형 트랩 내에 있는 물이 동결되지 않는다는 것을 알 수 있다.

목차

ABSTRACT
 요약
 1. 서론
 2. 연구방법
  2.1 시뮬레이션 프로그램의 개요
  2.2 시뮬레이션 대상
  2.3 시뮬레이션에 사용한 물성 데이터
  2.4 시뮬레이션 도구 및 조건
 3. 연구결과 및 고찰
  3.1 토양이 습한 상태의 경우
  3.2 토양이 일반적인 상태의 경우
  3.3 토양이 건조한 상태의 경우
 4. 결론
 References

저자정보

  • Changwoo Lee Dept. of Fire & Disaster Protection Eng ineering, Korea Soongsil Cyber Univ, #204, Jongno Biz-well, 23 Samil-daero 30-gil, Jongno-gu, Seoul, 110-340, Korea
  • Seungju Oh Department of Architecture, University of Kwangwoon, Kwangwoon-ro 20, Nowon-gu, Seoul, Republic of Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.