초록

영어

Local wall thinning elbow due to the water flow is one of the main degradation phenomenon in carbon steel pipe of plant system. The API579 code of FFS (fitness for service) used in the chemical plant gives a guideline to protect local wall thin problem in a straight pipe, but it does not include an elbow. In this study, the locally wall thinned elbow, which is considered an extrados or intrados wall thinned elbow, was carried out considering in-plane or out-plane bending using FEM (finite element method) analysis, and some of results were also compared with the experimental data. The results could give the structure integrity assessment to protect the local wall thinned elbow.

한국어

국부적인 두께감소 문제에 대하여 직관부위를 대상으로 한 건전성 평가는 잘 알려져 있으나 엘보우를 대상으로 한 건전성 평가는 최근에 원자력 분야에서는 많은 연구가 이루어지고 있으나 석유화학 플랜트에서 이용되는 건전성 평가 지침서 중 하나인 API579 코드에는 아직 없는 실정이다. 이에 본 연구에서는 엘보우를 대상으로 엘보우의 외부(extrados)와 내 부(intrados)에 두께 감소가 있다고 가정한 후 유한요소해석법을 이용하여 두께감소된 엘부 우의 건전성평가 해석을 수행하였다. 본 해석 결과는 석유화학 플랜트에서 이용되는 엘보 우의 건전성 평가에 이용될 수 있음을 보여주었다.

목차

ABSTRACT
 요약
 1. 서론
 2. 유한요소해석
 3. 해석 결과
 4. 결론
 References

저자정보

  • Ungburm Jang Department Beauty of Hanse University of Hansero 30 , Gunpo Gyeonggi-do 435-742, Republic of Korea
  • Kyuin Shin Korea Disaster & Safety Institute, Gwacheon, Gyeonggi-do 427-800, Republic of Korea
  • Sungho Lee Central Research Institute, Korea Hydro & Nuclear Power (KHNP) Company, Deajeon 34101, Republic of Korea
  • Changhee Kuan Department Beauty of Hanse University of Hansero 30 , Gunpo Gyeonggi-do 435-742, Republic of Korea

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.