원문정보
피인용수 : 0건 (자료제공 : 네이버학술정보)
초록
영어
The key device of power supply for ozone production process with DBD can cause the distortion of voltage and current and seriously affect the input power measurement and control. This paper presents a power measurement method based on quasi-synchronous algorithms for ozone production process with DBD and designs the power control strategy based on the load frequency tracking phase shift PWM mode. The experimental results show that the accuracy of power measurement can reach 0.3% and the accuracy of power control can reach 5%.
목차
Abstract
1. Introduction
2. The Influence of Harmonic on Power Measurement
3. The Power Measurement Based on Quasi-Synchronous Algorithms
3.1. Quasi-Synchronous Algorithms
3.2. The Power Measurement of Ozone Production Process with DBD
4. The Power Control Strategy Based on the Load Frequency Tracking Phase Shift PWM Mode
5. Conclusions
References
1. Introduction
2. The Influence of Harmonic on Power Measurement
3. The Power Measurement Based on Quasi-Synchronous Algorithms
3.1. Quasi-Synchronous Algorithms
3.2. The Power Measurement of Ozone Production Process with DBD
4. The Power Control Strategy Based on the Load Frequency Tracking Phase Shift PWM Mode
5. Conclusions
References