Fault Diagnosis Research for Power System Based on Timing Constraint Fuzzy Directed Graph

초록

영어

By taking full use of the temporal information of alarm message for quick and accurate diagnosis is very important. This paper presents an effective method for fault diagnosis, based on the time constraint fuzzy directed graph (TCFDG), in order to solve the cases of incomplete alarm information. An improved recognition algorithm is proposed which can effectively recognize misreports, missing messages and timing inconsistencies etc. And false alarms are filtered to overcome the deficiencies of incomplete alarm information, and to provide protection for the precise positioning of faults. Then, a reasoning method based on TCFDG is proposed, and use min operator and multiplication operator to determine the fault source, and use incidence matrix reduction method, reducing the dimension of the matrix, improved operational efficiency. Finally, a typical power system compared with some other typical methods was shown for demonstrating the feasibility and efficiency of the proposed method.

목차

Abstract
 1. Introduction
 2. Alarm Information Recognition Method Based on timing Constraints
  2.1 The Timing Characteristics of Alert Information
  2.2 Error Alert Message Classification
  2.3. Timing Constraints Information Processing Method
  2.4. Alert Messages Recognition Algorithm
 3. Description of Fuzzy Directed Graph
  3.1. The Definition of Directed Graph
  3.2. Fuzzy Directed Graph
 4. Fault Diagnosis Based On FTCDG Model
  4.1. Create the TCFDG Model
  4.2. The Reasoning Algorithm of CFDG
  4.3 The Flowchart of System
 5. TCFDG Incident Matrix Reduction
  5.1. Simulation and Analysis
 6. The Power System Fault Diagnosis Simulation Based on TCFDG and Performance Analysis.
  6.1. Case Study
  6.2 Performance Analysis.
 7. Conclusion
 References

저자정보

  • Chen Jin-yin Zhejiang University of Technology, Hangzhou310000,China
  • He Hui-hao Zhejiang University of Technology, Hangzhou310000,China
  • Zhou Xiao Zhejiang University of Technology, Hangzhou310000,China
  • Yang Dong-yong Zhejiang University of Technology, Hangzhou310000,China

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

      0개의 논문이 장바구니에 담겼습니다.