earticle

논문검색

<생산기술>

캐드 시스템을 이용한 치과용 가변형 상하악 트레이의 재현성에 관한 연구

원문정보

A Study on Reproduction of Adjustable Upper and Lower Dental Impression Tray by Using a CAD System

차영엽

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Development of a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper and lower dental impression tray was performed. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper and lower arch. The adjustable upper and lower stock tray showed clinically acceptable accuracies of the study cast produced by them.

목차

Abstract
 1. 서론
 2. Scanning 시스템
 3. 재현성 실험
 4. 결론
 후기
 References

저자정보

  • 차영엽 Young-Youp Cha. Member, Division of Mechanical & Automotive Engineering, Wonkwang University

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.