Cool-down test of HWR cryomodule for RAON

초록

영어

The heavy ion accelerator that will be built in Daejeon utilizes four types of superconducting cavities. Cryomodules holding the superconducting cavities in them supply thermal insulation for cavities operating in 4.3 K or 2.1 K. A Prototype of cryomodule which holds two HWR (Half Wave Resonator) cavities was fabricated and tested. Since the operating temperature of the HWR is 2.1 K, the superfluid helium was generated with warm vacuum pumping system. The cyromodule was successfully cooled down below lambda point temperature of helium and any detectable leak was not observed during the test. The static thermal load at 4.2 K was measured. The result and the experience for the cool-down below lambda point of helium are reported in this paper.

목차

Abstract
 1. INTRODUCTION
 2. HWR CRYOMODULE
 3. PERFORMACE TEST
  3.1. Experimental setup and cool-down
  3.2. Static thermal load measurement
  3.3. 2 K pump-down
 4. CONSLUSION
 ACKNOWLEDGMENT
 REFERENCES