영어



Seismic performance of a ten story reinforced concrete building is estimated using SAP2000. Performance based design method is the basis in the analysis where nonlinear static analysis called pushover method is combined with the seismic hazard to calculate expected performance of the building. A capacity curve as a result of the pushover analysis represents the relationship between base shear versus target displacement, and is essential to identify the two different behaviors of plastic hinges, force controlled and deformation controlled actions. The lateral displacement from the performance point revealed that the building was capable of sustaining a medium level of seismic load. It was also clear that the building behaved in the strong column-weak girder mechanism. The hinges formed in the girders are in dangerous level according to the performance category specified in ATC-40 and need to be strengthened.

한국어

Sap2000을 이용하여 성능기반설계법에 의거하여 10층 철근콘크리트 구조물의 내진성능을 조사해본다. 성능기반설계법은 푸쉬오버라 부르는 비선형정적해석법과 지진위험도를 복합하여 건물의 기대 성능을 추정하는 방법이다. 푸쉬오버해석의 결과로 얻은 능력곡선은 밑면전단력과 목표변위의 상관관계를 보여주며 소성힌지의 변위 및 하중주도 형태의 거동에 따른 차이점을 나타낸다. 해석 대상인 구조물의 성능점에 의하면 이 건물은 정도의 지진에 견딜 수 있으며 강기둥-약보로 거동함을 명확히 알 수 있었다. 보에 형성되는 힌지들은 ATC-40에 의할 때 위험수준에 도달하고 있으며 보강이 필요한 것으로 조사되었다.

목차

Abstract
 1. 서론 및 연구의 목적
 2. 지진하중
 3. 푸쉬오버해석
  3.1 성능기준
  3.2 소성힌지
 4. 해석 사례
 5. 결론
 참고문헌