earticle

논문검색

Effect of Twisted – Tape Tubulators on Heat Transfer and Flow Friction inside a Double Pipe Heat Exchanger

초록

영어

Computational fluid dynamics (CFD) has been employed for the Heat exchanger efficiency of a counter flow heat exchanger. The Heat exchanger efficiency has been assessed by considering the computed Nusselt number and flow friction characteristics in the double pipes heat exchanger equipped with two types twistedtapes: (1) single clockwise direction and (2) alternate clockwise and counterclockwise direction. Cold and hot water are used as working fluids in shell and tube side, respectively. Hot and cold water inlet mass flow rates ranging are between 0.04 and 0.25 kg/s, and 0.166 kg/s, respectively. The inlet hot and cold water temperatures are 54 and 30 C, respectively. The results obtained from the tube with twisted-tapes insert are compared with plain tube. Nusselt number and friction factor obtained by CFD simulations were compared with correlations available in the literature. The numerical results were found in good agreement with the results reported in literature.

목차

Abstract
 1. INTRODUCTION
 2. DATA REDUCTION EQUATIONS
 3. CFD MODELING
 4. RESULTS AND DISCUSSION
 5. CONCLUSION
 REFERENCES

저자정보

  • Sutida Phitakwinai Rajamangala University of Technology Suvarnabhumi, Nonthaburi, Thailand
  • Wanich Nilnont Rajamangala University of Technology Suvarnabhumi, Nonthaburi, Thailand
  • Kosart Thawichsri Siam Technology College, Bangkok, Thailand

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.