earticle

논문검색

Experimental Study of Lead-acid Battery Remaining Capacity Measuring in Photovoltaic Energy Storage System

초록

영어

The combination of ampere-hour method and open-circuit voltage method in the photovoltaic measurement system is studied in this paper. In order to achieve the purpose of online measurement for remaining capacity, the influence of internal battery discharge and temperature on the battery capacity should be considered. The battery capacity decreases by the increasing charging times, and the increasing terminal voltage difference causes the inaccurate measurement of the capacity of battery. In this paper, two experimental measurement methods are employed, which are complementary to each other, to make the system measurement more accurate and extend the life of lead-acid batteries. If the charging process of photovoltaic system is unstable, an optimization of lead-acid battery applications in photovoltaic energy storage system is explored at the same time. Finally, an illustrative example is presented to demonstrate the effectiveness of the proposed measuring method.

목차

Abstract
 1. Introduction
 2. Relations of Lead-acid Battery Terminal Voltage and Remaining Capacity
 3. Research of the Remaining Capacity Prediction by Ampere-hour Method
 4. Study on the Combination of Ampere-hour Method and Open-Circuit Voltage Method
  4.1 Study on the Influence of the Battery Self-discharge Measurement Method
  4.2 Study on the Changing for va, vb by Battery Aging
  4.3 Relationship between Released Capacity and the Discharge Current
  4.4 Temperature Compensation Design for Batter Measuring System
 5. Summary
 References

저자정보

  • Xiaoju Yin School of Electrical Engineering, Shenyang University of Technology, Shenyang, 110870, China, School of Renewable Energy, Shenyang Institute of Engineering, Shenyang, 110136, China
  • Fengge Zhang School of Electrical Engineering, Shenyang University of Technology, Shenyang, 110870, China
  • Xiuping Wang School of Renewable Energy, Shenyang Institute of Engineering, Shenyang, 110136, China
  • Yonggang Jiao School of Electrical Engineering, Shenyang University of Technology, Shenyang, 110870, China
  • Zhenghe Ju School of Renewable Energy, Shenyang Institute of Engineering, Shenyang, 110136, China