원문정보
초록
영어
The multi-smoke projectile launching system, as part of an active protection system, is an important equipment in the protection of a tank. During the field operation of the tank, the multi-smoke projectile launching system failed to function. As a result of dismantling inspection the multi-smoke projectile launching system, it was confirmed that the gear shaft of the reducer was failed. Therefore, a finite element analysis on the gear shaft of the reducer in the multi-smoke projectile launching system was conducted with regards to the operation conditions of the tank. As a result of conducting the analysis, there was a possibility of the gear shaft being damaged. Finally improvements on the reducer of the multi-smoke projectile launching device are expected to be conducted in the future by utilizing the result of this study.
목차
1. 서론
2. 감속기 기어축 파손확인
3. 감속기 기어축 파손원인 분석
3.1 감속기 동특성해석
3.2 감속기 기어축 유한요소해석
4. 결론
References