원문정보
초록
영어
Coordinated multi-point (CoMP) has been raised to increase the average cell throughput and the cell-edge user throughput. However, the energy consumption of mobile stations (MSs) is a key problem restricting the wide application of CoMP systems. Considering the energy consumption of feeding back channel state information (CSI) by MSs and the influence of CSI accuracy on the throughput of system, it is proposed to measure the relationship between feedback energy consumption and throughput with energy efficiency feedback utility (EEFU) function which can adapt to different application scenes by adjusting utilization coefficient. The feedback utilization of two precoders in CoMP systems is analyzed respectively, including the optimization allocation of feedback bits with utility function. The complete EEFU optimized expression and the optimizing flow path satisfying the actual application demands of CoMP systems are then derived. The simulation results illustrate the practicability and necessity of the EEFU function and verify the performance of EEFU with different precoders.
목차
1. Introduction
2. System Model
3. Energy Efficient Feedback Design
3.1. EEFU Function for CoMP
3.2. EEFU for CoMP based on MRT Precoding
3.3 EEFU for CoMP based on MMSE Precoding
4. Simulation Results
5. Conclusions
Acknowledgements
References