earticle

논문검색

발포제를 이용한 PET/CT의 유용성

원문정보

The Utility of Used a Blowing Agent in PET/CT

김기진, 임재동, 유세종, 김정호

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

When scanning PET/CT, dose not unwrinkle gastric folds can be difficult to diagnose gastric cancer. In this study, we use an blowing agent to evaluate the extension the stomach and usefulness of it. The study enrolled 30 patients who patient with uptake in stomach between January and February 2013. Stomach extension was described as the vertical length of the Water drink group was 61.7±9.7 mm, horizontal length was 102.5±17.6 mm and the vertical length of the Blowing agent group was 74.1±10.7 mm, horizontal length was 101.5±14.8 mm in transverse section. Stomach extension was described as the vertical length of the Water drink group was 109.3±18.8 mm, horizontal length was 62.7±18.4 mm and the vertical length of the Blowing agent group was 123.1±23.1 mm, horizontal length was 87.6±14.9 mm in coronal section. Water drink group SUV decreased 35% and Blowing agent group SUV decreased 56%. Blowing agent group extension was similar or superior than water drink group. Therefore, when using a blowing agent will be able to help clinical.

목차

Abstract
 1. 서론
 2. 대상 및 방법
  2.1 대상
  2.2 방법
 3. 결과
  3.1 위장의 확장정도
  3.2 표준섭취계수의 변화
 4. 결론 및 고찰
 5. References

키워드

저자정보

  • 김기진 Ki-Jin Kim. 건양대학교병원 영상의학과
  • 임재동 Jae-Dong Rhim. 대원대학교 방사선학과
  • 유세종 ·Se-Jong Yoo. 건양대학교병원 영상의학과
  • 김정호 Jeong-Ho Kim. 건양대학교병원 방사선종양학과

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.