영어
This paper presents an improved ip - iq detection method for three-phase four-wire electric arc furnace (EAF) systems based on the instantaneous reactive power theory, which can be applied not only to stationary load, but also to non- stationary load with large fluctuations in electrical parameters. Simulation experiments show that this detection method is indeed capable of fundamental and harmonic separation to achieve the purpose of harmonic detection.