원문정보
초록
영어
The aim of the present study was to carry out quantitative analysis of spatial resolution for the influence of the focus size and digital image post-processing on the Computed Radiography (CR). The modulation transfer functions of an edge measuring method (MTF) was used for the evaluation of the spatial resolution. The focus size of X-ray tube was used the small focus (0.6 mm) and the large focus (1.2 mm). We evaluated the 50% and 10% of MTF for the enhancement of edge and contrast by using multi-scale image contrast amplification (MUSICA) in digital image post-processing. As a results, the edge enhancement than the contrast enhancement were significantly higher the spatial resolution of MTF 50% in all focus. Also the spatial resolution of the obtained images in a large focus were improved by digital image processing. In conclusion, the results of this study should serve as a basic data for obtain the high resolution clinical images, such as skeletal and chest images on the CR.
한국어
본 연구의 목적은 컴퓨터 방사선영상에서 X-선 초점 크기와 디지털영상후처리에 따른 공간분해능을 정량적 으로 분석하고자 하였다. 초점의 크기는 소초점(0.6 mm)와 대초점(1.2 mm)을 이용하였다. 공간분해능의 정량적 분석 은 엣지 측정법의 변조전달함수(MTF)를 이용하였다. 디지털영상후처리는 다단계 이미지 대비 증폭 알고리즘을 이용 하여 경계면 증강과 대조도 증강에 따른 50%와 10%의 MTF를 평가하였다. 그 결과 모든 초점에서 MTF 50%의 공 간분해능이 대조도 증강보다 경계면 증강에서 유의하게 높았다. 또한 대초점에서 획득된 영상은 디지털영상처리를 통해 공간분해능이 향상되었다. 결론적으로 이러한 결과는 컴퓨터 방사선영상에서 골격계 및 흉부영상과 같은 고 공 간분해능 임상영상을 얻기 위한 기초자료로 활용할 수 있다.
목차
Abstract
1. 서론
2. 재료 및 방법
2.1 재료
2.2 실효초점 측정
2.3 MTF 영상획득 방법
2.4 영상후처리 조건
2.5 공간분해능 측정
2.6 통계적 분석
3. 결과
3.1 실효초점의 측정 결과
3.2 MTF 곡선 평가
3.3 MTF 50%와 10%의 정량적 결과
4. 고찰
5. 결론
REFERENCES