원문정보
A Study on simulation analysis of UVGI air sterilizer installation in a car for microbiological safety
초록
영어
The recent rise in SARS and bird flu infections around the world has raised the interest in studying the habits of air borne pathogens such as germs and viruses. In this study, simulations were carried out to predict the performance of UVGI air sterilizer at preventing airborne infections inside a car, based on the installation position and the removing effect of the UVGI air sterilizer. Simulation results showed that the UVGI air sterilizer was most effective when located at the rear side of the front seats. It was also showed that when the out-air mode and the UVGI air sterilizer were set to the highest capacity, the microbial safety levels were maintained in a car for 21 hours.
목차
1. 서론
2. 모델링
2.1 CFD 유동모델
2.2 Particle transport 모델
2.3 운전자 및 동승자 모델
2.4 UVGI 살균장치 모델
2.5 자연제거 모델
2.6 Multi-zone 모델
2.7 모델 해석
3. 결과 및 분석
4. 결론
5. References