A Study on the Correction Factor of Optic Scattering PM2.5 by Gravimetric Method
초록
영어
In order to more accurately operate the Dusttrak equipment of optic scattering measurement used for measurement ofthe fine particle (PM2.5), the correction factor of optic scattering was estimated based on the result of gravimetricmeasurement. The number of samples taken in the spring of 2013 was 5 days respectively, the average PM2.5 concentrationof optic scattering was shown to be about 2 times higher than that of gravimetric and β-ray method; and the result ofestimating the gradient of the linear regression line between the gravimetric and optic scattering, between the β-ray methodand optic scattering as the correction factor using ordinary least squares were shown to be 0.57 and 0.61 respectively. Considering that PM2.5 density varies depending on the season and place, it is presumed that the estimation of thecorrection factor is required to be conducted continuously.
한국어
미세먼지를 측정하기 위하여 사용되고 있는 광산란법 장비를 보다 정확하게 운영하기 위하여 중량법 측정결과를 기준으로 보정계수를 산정하였다. 2013년 5월 제주도 애월읍에서 채취된 시료의 표본개수는 장비별로 각각 5개로, PM2.5 농도는 광산란법이 중량법과 베타선법에 비하여 약 2배 가량 높은 수준으로 나타났으며, 최소자승법을 이용한 중량법과 광산란법, 베타선흡수법과 광산란법의 선형회귀직선의 기울기를 보정계수로 산정한 결과 그 값은 각각 0.57, 0.61이었다. 계절과 장소에 따라 미세먼지의 밀도에 차이가 있음을 고려할 때 광산란법 측정결과는 중량법 또는 이와 동등한 측정방법을 기준으로 보완될 필요가 있으며, 이에 따른 보정계수 산정은 지속적으로 수행되어야 할 것으로 판단된다.