Effects of Conducted Noise on Long Power Cable Considering Submarine Environment

원문정보

초록

영어

In this paper, we analyze the conducted noise level of a long cable considering a subsea environment. Because conducted noise causes distortion for a signal and power line, it must be removed. As it have a negative effect on system reliability. Thus, we analyzed the effects of the conducted noise, which is caused by the temperature at the depth of the sea. To design conducted noise, we transformed the effect of the temperature changes influencing the cable into an equivalent circuit, and co-simulated it with FEM (finite element model) tools. This method allowed us to propose a proper design method for a long cable and determine the relationship between the noise and temperature.

목차

Abstract
 1. Introduction
 2. Analysis of Factors Acting on Cables
  2.1 Occurrence of Transient Voltage
  2.2 Capacitance Change with Respect to Temperature
 3. Simulation of Temperature Change in Cables
  3.1 Configuration of the Thermal System
  3.2 Cable Modeling
 4. Simulation and Results
 5. Conclusion
 Acknowledgments