earticle

논문검색

후막형 전기히터를 이용한 전기보일러 성능평가

원문정보

A study on the Performance of electric boiler using thick- film heater

장인성, 강정길

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

The performance of electric boiler using thick-film heater has been investigated experimentally. Electric boilers are using thick film heater is composed of four to a water chamber. In this study, the water flow rate while changing then umber of heaters and heating performance was evaluated. One water chamber, the average heat release is approximately 6.63kW. And average heat release of four water chamber is about 29.08kW. The energy efficiency of the water chamber 4 was 95.4%. Finally, the average heat release and energy-efficiency of electric boiler is increased with increasing water chamber number.

목차

Abstract
 1. 서론
 2. 실험장치 및 방법
  2.1 실험장치
  2.2 실험방법
 3. 결과 및 검토
  3.1 히터 설치 대수에 따른 평균방열량
  3.2 히터 설치 대수에 따른 평균 효율
 4. 결론