전자제어 밸브(ECV) 내부로 유입되는 냉매의 유동 특성에 관한 연구

원문정보

A Study on the Refrigerant Flow Characteristics Flowing into the Interior of the Electromagnetic Control Valve

김대영, 조행묵

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

In this paper, we analyzed the characteristics of the mass flow rate and velocity of the refrigerant in response to a change in the number of holes and the diameter size(Type-1~4) of the valve guide refrigerant to flow from Pc to Ps when the pressure is constant. Type-1 is 40% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-2 is 64% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-3 is 50% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-4 is 47% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate.