원문정보
Ventilation Characteristics of Filtration Basin in Water Treatment Plant using 3-D CFD Simulation
초록
영어
In this paper, the ventilation characteristics of a filter basin of the purification plant were investigated for different windows size and the locations by numerical simulation. It has been found that the maximum concentration of chlorine gas in the filter basin with original windows was predicted about 0.13ppm. It means that an additional required amount of ventilation is needed to maintain good indoor air quality. For the filter basin with double sized windows and relocations, the maximum concentration of chlorine gas was predicted 0.11ppm. It is known that the window size and its locations in a filter basin of the purification plant are important factors to reduce the concentration of chlorine gas in the indoor.
한국어
본 연구에서는 창문의 크기와 위치를 달리하여 정수장 여과지동의 환기특성을 3차원 전산유체역학 프로그램을 이용하여 해석하였다. 그 결과 기존 창문의 위치와 크기를 갖는 여과지동에서 최대 염소가스의 농도는 0.13ppm 으로 나타났다. 이것은 좀 더 쾌적한 실내 공기질을 유지하기 위해서 추가적인 환기량이 필요함을 의미한다. 정 수장 여과지동의 창문의 크기를 2배로 늘리고 재배치한 경우, 실내 염소가스의 최대농도는 0.11ppm으로 감소하 였다. 따라서 정수장 여과지동의 염소가스를 줄이기 위해서 환기량과 환기구 위치가 중요함을 알 수 있었다.
목차
국문초록
Ⅰ. 서론
Ⅱ. 대상 모델
Ⅲ. 수치해석 방법
Ⅳ. 결과 및 검토
Ⅴ. 결론
References
참고문헌