원문정보
Characteristics of Wind Pressure Distribution for the Solar Collector with Various Separation Distance
초록
영어
The solar collectors were affected by Typhoon Bolaven last year, because they are mainly a lightweight structure and directly exposed to the outside. Nevertheless, a study on wind pressure of solar collector is not sufficient. Therefore, It is necessary that a study be conducted to discover the effect of separation distance on solar collectors. This study conducted the wind tunnel test to analyze the distribution of the wind pressure in accordance with the separation distance of solar collectors. wind tunnel test conducted by changing separation distance to 0.3m, 0.5m, 1.0m. As a result, the study can be the useful basic data to set standards for safety technology in the solar collector.
목차
1. 서론
2. 실험방법 및 실험조건
2.1 풍동 기류
2.2 실험 모형
2.3 실험 데이터 측정방법
2.4 실험 데이터 해석방법
3. 실험결과 분석 및 고찰
3.1 어레이 이격거리별 최대 풍압계수
4. 결론
참고문헌