초록

영어

An experiment to investigate the natural circulation of a cryogen has been performed. The study is motivated mainly by our recent development of cryogenic cooling system for prototype superconducting cyclotron without any circulating pump. In the natural circulation loop system, a cooling channel is attached on the outer surface of the aluminium block and the liquid nitrogen passes through inside of the channel to cool the block indirectly. A cryocooler as a heat sink is located at the top to re-condense cryogenic vapor coming from the aluminium block in which electrical heater is installed as a heat source. The main dimensions are determined using the relevant analysis and the natural circulation loop is successfully fabricated. The temperature distributions in the loop are measured during initial cool-down process and in steady state, from which the modified Grashof numbers are calculated and compared with the existing correlation estimated with one-dimensional analysis for steady state flow.

목차

Abstract
 1. INTRODUCTION
 2. NATURAL CIRCULATION LOOP
 3. EXPERIMENTAL APPARATUS
 4. RESULTS AND DISCUSSION
 5. CONCLUSIONS
 ACKNOWLEDGMENT
 REFERENCES

저자정보

  • Yeon Suk Choi Korea Basic Science Institute, Daejeon, Korea

참고문헌