초록

영어

A three dimensional numerical analysis was performed to study the cooling performance of xEV battery module depending on cooling fluid inlet position. Depending on the inlet position from the top, case 1 (top inlet), case 2 (middle inlet), and case 3 (bottom inlet) are selected. For the case 1, the temperature of the battery near inlet was higher than that of the battery near outlet. For the case 2 and 3 the temperature of the battery near inlet was lower than that of the battery near outlet. From the analysis result, the cooling performance is higher in the order of case 2, case 3, and case 1.